Controls for industrial automation, vehicle automation, signal
converter, signal conditioning, signal translation, current, voltage, resistive, PWM, PWM
signal, CAN bus automation, SAE J1939 control systems, control panels, industrial control, signal amplifier,
machine automation, test equipment.
|
CAN bus Dual Universal Signal Conditioner
|
Technical Specifications: |
Dual Universal Signal Conditioner, SAE J1939 |
| Order Code: |
P/N: AX130500 |
| CAN Port: |
SAE J1939 (CANopen on request) |
| Inputs: |
2 Universal Signal Inputs
User programmable as:
Voltage (0-1V, 0-2.5V, 0-5V or 0-10VDC);
Current (0-20 mA or 4-20 mA);
Resistive;
PWM; Frequency;
or Discrete Digital Signal Input.
Refer to the Technical datasheet for details. |
| Outputs: |
Up to 2 signal outputs can be selected.
Outputs are user programmable as:
0-5VDC;
0-10VDC;
0-20 mA;
4-20 mA;
or PWM Signal.
Refer to the Technical datasheet for details. |
| Power: |
12V, 24V or 48VDC nominal |
| Packaging: |
Aluminum enclosure, integral Deutsch IPD connector, Nitrile gasket
Encapsulated
4.27 x 4.27 x 2.14 inches 108.49 x 108.49 x 54.28 mm
L x W x H including integral 12-pin connector |
| Electrical Connections: |
12 pin Deutsch IPD connector P/N: DT15-12PA
A mating plug kit is available as Axiomatic P/N: AX070105. |
| Protection Rating: |
IP67 |
| Operating Conditions: |
-40 to +85°C |
| PDF Datasheet: |
Click icon for PDF datasheet |
|
Applications:
- CAN bus Networked Automation
- Precision Signal Conversion
- CAN bus Networked Vehicle Control Systems
- Test Equipment
- Machine Automation

Other PWM conversion products
CAN Signal Controls, I/O |
|