| Technical Specifications: |
Connector Amplifier - 0-5 VDC/0-20mA/Potentiometer Input Version
P/N: CAPV-H-5V-x complete with cable CAPV-6C-yM
Where: x = maximum current output (2A, 1.2A, 800mA or 600mA)
y = cable length (2 meters is the standard length) |
Order Codes: |
P/N:
CAPV-H-5V-2A c/w CAPV-6C-2M (2 Amp max. output )
P/N:
CAPV-H-5V-1.2A-6C-2M (1.2 A max. output)
P/N: CAPV-H-5V-800MA-6C-2M (800mA max. output)
P/N:
CAPV-H-5V-600MA (600 mA max. output)
|
| Operating voltage (power supply
requirement): |
9 to 28 VDC power supply range
Accepts up to a maximum of 32 VDC |
| Control input signal options: |
0-5 VDC voltage signal or
0-20 mA current signal or
10K Potentiometer (accepts 2.5K to 50K pots) or
for soft shift control, pre-set the connector amplifier
by connecting +5VDC to input and using the Imax
adjustment
(4-20mA or 0-10VDC input versions are also
available.) |
| Input resistance: |
Voltage mode: 125K Ohms
Current mode: 50 Ohms |
| Range of maximum output current: |
2A, 1.2A, 800mA, or 600mA version available |
| Solenoid resistance selection (nominal): |
Nominal resistance of solenoid coil should comply with:
Rcoil < (Vpower supply - 1.5 V)/I-max. |
| Internal supply for setpoint potentiometer: |
+5 VDC |
| Electromagnetic
compatibility (EMC): |
Emission EN 50081-2
Immunity EN 50082-2 |
| Approvals: |
CE |
| Electrical
connection: |
DIN 43650 plug
2 meters jacketed cable, 6 conductor 18AWG
(A version for remote mounting is also available.) |
| Protection
class: |
IP65 when correctly installed with lid, compression
washer, o-ring and base gasket |
| Operating
conditions: |
-40 to +85°C (-40 to 185°F) |
| Dimensions: |
See datasheet for dimensions |
| PDF Datasheet: |
Click icon for PDF datasheet |