ANALOG and DIGITAL FAN CONTROLLERS FOR HYDRAULIC FAN DRIVE SYSTEMS:
0-5V INPUT, SINGLE OUTPUT
PWM INPUT, SINGLE OUTPUT
USER CONFIGURABLE FAN CONTROLLER, MULTIPLE I/O
MULTIPLE INPUTS, SINGLE OUTPUT, RS-232
OPEN LOOP, SINGLE INPUT
ANALOG FAN
CONTROLLERS |
CAPV-H-5V-2A
- DIN 43650 coil mount
- Interfaces to a 0 to 5V, 0 to 20mA or potentiometer command input
- Accepts 9 to 32VDC power supply
- Provides an adjustable maximum 2 Amp
output
- Minimum current, maximum current,
ramp times, dither level and frequency fully adjustable
- Output proportional to input (reverse
logic available)
- Complies to EMC Directive (CE
mark)
- Environmental ratings: IP65, -40 to 85 degrees C (-40 to 185 degrees F)
|
| PWM INPUT, FAN
CONTROLLERS |
PWMC-PCB-2A - ANALOG remote
mount PCB card OR PWMC-SMB-2A-IP7-1.5M -
ANALOG remote mount metal box, cable
Go
to datasheet.
PWMC-DR-2A - ANALOG
controller mounts on a DIN rail
Go
to datasheet.
|
MULTIPLE INPUT
PROGRAMMABLE FAN
CONTROLLERS |
Multipurpose Fan Controller, Dual
Output
Application Platforms - Contact Axiomatic with your specification.
AX020300 - Go
to datasheet.
Contact the
manufacturer for a part number upon ordering.
- Standard software is available.
- Wide range of power supply inputs (12
or 24 VDC nominal)
- Provides independent outputs for up
to two solenoid valves (proportional or on/off).
- Can interface to HydraForce TS valves
(0A: Valve closed - Fan runs at maximum speed; Maximum A output:
Valve fully open - Fan is idling)
- Can drive the PV series of
proportional cartridge valves.
- Accepts up to 3 temperature sensor
inputs (i.e. engine oil, coolant, water, charge air)
- Commanded by up to 3 active low
digital inputs (interface to switches, fan reverse and other fan
control commands, etc.)
- PWM input interfaces to engine ECM or
other frequency input
- Universal analog input (0-5V, 0-10V,
4-20 mA, 0-20 mA)
- Controls fan speed within a range of
temperatures or to an individual setpoint
- IP67 rating
- -40 to 85 degreesC (-40 to 185 degrees F) - Other temperature ranges can be accommodated.
- RS232 communications for interface to
a PC or Laptop used for configuration or diagnostics.
|
Economy Fan Controller, Single
Output
Application Platforms - Contact Axiomatic with your specification.
AX020200 Series - Go
to datasheet.
- OEM designs are accommodated with
factory programming
- Wide range of power supply inputs (12
or 24 VDC nominal)
- Drives one solenoid valve
(proportional or on/off).
- Can interface to HydraForce TS valves
(0A: Valve closed - Fan runs at maximum speed; Maximum A output:
Valve fully open - Fan is idling)
- Can drive the PV series of
proportional cartridge valves.
- Accepts up to 3 temperature sensor
inputs (i.e. engine oil, coolant, water, charge air) using NTC or
PTC type temperature sensors - linear response preferred
- Multiple Digital Inputs - 4 available
(active high or active low) for climate control, speed reduction
or quiet mode, machine drive functions, etc.
- Controls fan speed within a range of
temperatures or to an individual setpoint
- Accepts a 0-5V pressure transducer
input.
- IP67 rating
- -40 to 85 degrees C (-40 to 185 degrees F) - Other temperature ranges can be accommodated.
- RS232 communications for interface to
a PC or Laptop used for configuration or diagnostics.
|
Fan Drive Controller - Multiple Inputs, Single Output - P/N: AX021500
Application Platforms - Contact Axiomatic with your specification.
|
|
The Fan Controller is designed for the electronic control of hydrostatic fan drive systems. Variable control of the rotational speed of a fan-drive motor provides maximum efficiency and noise control for operation of the engine cooling fan system.
Applications include: motor vehicles (trucks and buses), agricultural equipment, construction equipment, and stationary power plants. Accepting multiple temperature sensor and digital inputs, the controller interfaces to a proportional relief valve. A standard controller is available for some applications.

Hydraulic Fan Controller - Multiple
Inputs
|
Application Platforms - Contact Axiomatic with your specification.
For application-specific requirements, please complete our checklist.
Specification Checklist

If you do not have Adobe Acrobat Reader installed, go to www.adobe.com and download Adobe Acrobat Reader.
|
|