| Technical Specifications: |
Hot Shot Coil Saver
Type: CS-xx-yyy
Where:
xx=holding power as a % of input power
yyy=initial output time interval (mSec) |
| Order Code: |
P/N: CS-32-380 |
Operating voltage (power supply requirement): |
10 to 36VDC nominal power supply (± 10% max.
ripple) |
Switching frequency : |
20 kHz |
Maximum output current at full power on
time: |
4A |
Full power on time: |
380 mSec. (standard)
Factory modified (range of 50 mSec. - 1 s)
Tolerance +/- 10% |
Holding power specification: |
32% of input power (standard)
Factory modified to within the range of 20 - 70% to
accommodate specific applications |
Electrical termination: |
Unterminated lead wires, 18 AWG, 48 inches long
(Alternate connection styles available upon request.)
The fuse between the power supply and the module should be sized to be larger
than the coil rating. |
Solenoid resistance selection (nominal): |
I-output (during full power on time): I-output=Vps/Rcoil
I-output (during holding power mode): I-output=(Vps/Rcoil) x DC
Where DC=duty cycle % (holding power specification) |
| Connections: |
Mount the unit using two screws or bolts (customer
supplied). |
Protection: |
IP67 |
Operating conditions: |
-40 to +85°C (-40 to 185°F)
0 to 93% relative humidity |
Dimensions:
(Alternate packaging available upon
request.) |
Encapsulated box (Lexan resin with metal lid)
50.64 x 69.88 x 16.42 mm (W x L x H)
1.99 x 2.75 x 0.65 inches |
| PDF Datasheet: |
Click icon for PDF datasheet |