Description:
The Remote Mount Solenoid Driver simplifies remote control of proportional
solenoids. The unit accepts 0-5 VDC, 0-20 mA or 10K potentiometer control
inputs and a wide range of power sources from 9-28 VDC. This linear solenoid
driver utilizes high frequency switching output (PWM) to provide a DC current.
Maximum current output options are 2 Amps, 1.2 Amps, 600 mA or 400 mA. The user
can adjust maximum and minimum current. Ramp time, dither frequency and
amplitude can be adjusted to match the application. A system of LEDs indicates
output power level, input power level and power on/off. It is CE certified for
EMC. The unit is available as a stand alone PCB board, as a packaged driver
enclosed in an IP65 or IP67 rated metal housing with cable provided or with 3
connectors. An industrial module in a DIN rail mount housing is available. OEM
versions are available. The valve driver is designed for remote mounting. Other
versions are available including 4-20
mA and 0-10 VDC signal input versions as well as a DIN 43650 coil mount version.
Function:
The Remote Mount Solenoid Driver supplies a solenoid valve with current
proportional to an input control (0-5 VDC, 0-20 mA, potentiometer or pre-set
level).
Application:
Accurate control of hydraulic and pneumatic proportional solenoid valves used
in mobile construction equipment and industrial processes.
|
|
|
|
Features:
- Remote mounting
- Stand alone PCB board, DIN rail mount module or enclosed
in a metal housing with cable (3 connectors or no cable optional)
- Maximum current adjustment does not affect minimum
current setting
- Broad range of supply voltages (9 to 28 VDC) with no
degradation in performance
- Current sensing circuit maintains output regardless of
changes in input voltage or coil resistance
- Modern technology utilizing high frequency switching
output (PWM)
- Energy efficient design (no heat sink is
required)
- Simple control with a 10K potentiometer or
sophisticated control with 0-5 VDC or 0-20 mA signal inputs
- Maximum current output options include 2 A, 1.2 A, 600
mA or 400 mA
- LED indication of output power level, input level and
power on/off
- Simple implementation of "soft shift" control
with minimal external components
- Electronic limiting circuit means no internal
fuses
- Short circuit proof (in case of solenoid failure or
miswiring)
- Reverse polarity protection
- CE certified for EMC
- Metal box version carries IP67 protection rating
- Filter eliminates electrical noise
|
|
|

PCB card version

DIN rail mount version
|

Technical
Specifications:
All specifications typical at nominal input voltage and 25 degrees C unless
otherwise specified.
General Specifications
Operating conditions
Storage temperature |
-40 to 85°C (-40 to 185°F)
-50 to 125°C (-58 to 257°F) |
| Protection |
Packaged Driver
IP65 with neoprene lid gasket installed and gray cable
IP67 with neoprene lid gasket installed and solid round black cable
The PCB and DIN rail mount versions are conformally coated and do not carry
a protection rating. They are designed to be housed in a control
cabinet. |
Electromagnetic compatibility (EMC)
- Packaged Driver |
Emission: EN 50081-2
Immunity: EN 50082-2 |
| Approvals |
CE (Packaged Driver)
The PCB Board and DIN rail versions are sold as components. |
Electrical connection
- PCB Board or Packaged Driver (no cable) and DIN rail mount
version |
10 screw terminals |
Electrical connection
- Packaged Driver with cable |
Unterminated cable - 5 ft. (1.5m) or 10 ft. (3m)
standard lengths
(A DIN 43650 version is also available.) |
Electrical connection
- Packaged Driver with 3 connectors |
Solenoid - Brad Harrison 45360-001 nano-change
receptacle (3-pole male)
Signal Input - Brad Harrison 45360-001 nano-change receptacle (3-pole male)
Power Input - Brad Harrison 8R4E06A18A120 micro-change single keyway receptacle
(4-pole male)
Mating plug with cable assemblies are available. Contact manufacturer.
|
Cable clamp (grommet) size
Max. cable diameter
Wire size - cable in IP65 rated Packaged Driver
Wire size - cable in IP67 rated Packaged Driver
|
PG9 screw type
5.0 to 7.92 mm (0.200 to 0.312 in.) solid round cable
9 insulated wires AWG 20 plus drain wire
1 twisted quad AWG 18 (1.0 mm²) and
5 insulated wires AWG 24 (0.25 mm²) plus shield |
| Dimensions - PCB Board |
63.5 x 20.3 x 63.5 mm (W x D x H)
2.5 x 0.8 x 2.5 inches |
| Dimensions - Packaged Driver with cable |
114.3 x 27.9 x 79.3 mm
4.500 x 1.099 x 3.125 inches
(W x D x H excluding grommet and cable) |
Dimensions - DIN rail mount
|
90.0 x 68.0 x 70.0 mm (W x L x H excluding DIN rail
foot)
3.54 x 2.67 x 2.75 inches |
| Dimensions - Packaged Driver with 3
connectors |
114.3 x 39.0 x 110.64 mm
4.50 x 1.53 x 4.35 inches
(W x D x H including mounting plate and connectors) |

Metal Box with 3
connectors

Electrical
Specifications
| Operating voltage |
9 to 28 VDC* (UL approved range)
Accepts up to a maximum of 32 VDC |
| Control input signal options |
0-5 VDC voltage signal, or
0-20 mA current signal, or
10K potentiometer (accepts 10K to 50K), or
for soft shift control, pre-set the driver by connecting +5VDC to input and
using the I-Max. adjustment
(4-20 mA or 0-10 VDC input signal versions are also
available.) |
| Range of maximum output current |
2 A, 1.2 A, 600 mA or 400 mA |
| Input resistance |
Voltage mode: 250K Ohms
Current mode: 33 Ohms |
| Solenoid resistance selection
(nominal) |
Rcoil<(Vpower
supply - 1.5V)/Imax |
| Internal supply for setpoint
potentiometer |
+5 VDC |
* Note:
- Match power supply voltage with rating of solenoid coil.
Operating the driver with a supply voltage lower than the solenoid rated
voltage may result in reduced maximum current output.
- Since the output is filtered (not switching), an external polarity or protection diode is not necessary.
- The maximum current output of the controller should not
exceed the current rating of the valve coil.
Adjustments
| Minimum current setting |
0 to 0.5 A (for 2 A output version)
0 to 0.3 A (for 1.2 A output model)
0 to 150 mA (for 600 mA output model)
0 to 100 mA (for 400 mA output version) |
| Maximum current setting |
0.6 to 2.0 A (for 2 A output version)
0.36 to 1.2 A (for 1.2 A output model)
180 to 600 mA (for 600 mA output model)
120 to 400 mA (for 400 mA output version) |
| Current ramp time |
0.01 to 5.0 seconds independent |
| Dither amplitude |
0 to 10% of rated maximum
current |
| Dither waveform |
Triangular |
| Current dither frequency |
70 to 350 Hz (+/- 10% of full
scale) |
Mounting
Instructions and Wiring Connections:
For stand alone PCB Boards:
Mounting the board:
- The board will accomodate #6 size mounting screws (not
supplied).
- Use a cable to connect to the driver with each wire
stripped to 6.5 mm (1/4 inch) and the shield (jacket) stripped to permit
splaying of the wires in the screw terminal without tension. The exposed ground
shield wire should have a heat shrink placed around the wire as a precautionary
measure. Size 16-20 AWG wire is recommended for the power and output
conductors. Size 18-24 AWG wire is recommended for the signal
conductors.
- Reference the label (included with the board) for the
pin out connections of the screw terminals.
- To connect the cable to the board, loosen each screw
terminal, wrap the wire around the screw and tighten with a jeweller's sized
screwdriver. Take care to position the ground shield wire away from the PCB
board.
For Packaged Drivers with/without cable (Metal
Box):
Mounting the housing:
Mount the housing using four #10-32 bolts or screws.
Connecting the cable:
For models where the cable is supplied, connect the cable to the load, power
supply and input signal or potentiometer as follows.
For Potentiometer, 0-20 mA or 0-5 VDC control:
Turn ramp trim pots fully counter clockwise to eliminate ramping.
Use Imin trim pot to set minimum speed with minimum control input.
Use Imax trim pot to set maximum speed with 100% of control input.
Enable:
When Enable is connected to the -ve power supply, the unit will be disabled.
When Enable is left open or connected to the +ve power supply, the unit is
enabled.
IP67 rated model - cable
IP65 rated model
- cable
For wiring
diagrams, request a faxed copy of the datasheet.
Connecting a cable to the screw terminals on the
board:
For models where no cable is provided, connect a cable as follows. For a cable
specification, refer to the technical specification section.
- To access the screw terminals, loosen the four screws on
the lid using a Phillips #1 screwdriver. Remove the lid.
- Use a 0.200 to 0.312 inch diameter solid round shielded
cable to connect to the driver. Each wire should be stripped to 6.5 mm (1/4
inch) and the shield (jacket) stripped to a minimum of 57 mm (2-1/4 inches).
Exposed ground shield wire should have a heat shrink placed around the wire as
a precautionary measure.
- Remove the clamp nut on the Heyco PG9 grommet using an
adjustable wrench.
- Slide the clamp nut over the cable. Insert the cable
into the grommet, allowing for the stripped minimum of 2 1/4 inches to be
available inside the housing. Tighten the clamp nut securely attaching the
cable to the housing assembly.
- Reference the label (found on the inside of the lid) for
the pin out connections to the screw terminals. The wiring connections diagram
(see previous section) shows the appropriate connections for each control
option.
- To connect the cable to the board, loosen each screw
terminal, wrap the wire around the screw and tighten with a jeweller's sized
screwdriver. Take care to position the ground shield wire away from the PCB
Board.
- Replace the lid and gasket. Replace and tighten the four
4-40 Phillips flat head screws.
For Packaged Drivers with 3 connectors:
Mounting the housing:
Mount the housing using four #10-32 bolts or screws.
Connector pin out:
For models where the cable is supplied, connect the cable to the load, power
supply and input signal or potentiometer as follows.
For Potentiometer, 0-20 mA or 0-5 VDC control:
Turn ramp trim pots fully counter clockwise to eliminate ramping.
Use Imin trim pot to set minimum speed with minimum control input.
Use Imax trim pot to set maximum speed with 100% of control input.
Enable:
When Enable is connected to the -ve power supply, the unit will be disabled.
When Enable is left open or connected to the +ve power supply, the unit is
enabled.
Mating plug and cable assemblies are available. Contact
the manufacturer.
For DIN rail mount
Drivers:
Mounting the housing:
The DIN Rail Mount Driver has a universal foot for mounting on the DIN rail.
Connecting to the screw terminals on the board:
- Use 16-20 AWG wire for the power conductors and 18-24
AWG wire for the signal conductors in a solid round shielded cable to connect
to the remote mount solenoid driver. Each wire should be stripped to 6.5 mm
(1/4 inch) and the shield (jacket) stripped to a minimum of 57 mm (2-1/4
inches). Exposed ground shield wire should have a heat shrink placed around the
wire as a precautionary measure.
- Reference the label for the pin out connections of the
screw terminals.
- To connect the cable, loosen each screw terminal, insert
the pre-tinned wire and tighten with a jeweller's sized screwdriver. Take care
to position the ground shield wire away from the PCB Board.
Enable: When Enable is connected to the -ve power
supply, the unit will be disabled. When Enable is left open or connected to the
+ve power supply, the unit is enabled.
Adjustment
Details:
The following settings represent a typical set up for a
voltage or current signal input operating scenario. Conditions will vary for
other set up scenarios. Adjustments are accessible by loosening the four screws
on the lid of the housing and removing the lid. Ensure that the unit is
connected to an operating proportional valve. Use a Phillips #1 screwdriver to
make adjustments to the trim pots.
|

PCB card or Packaged Driver
|

DIN rail mount version |
Trim Pot Adjustments
Trim pots are single turn. |
Range of Adjustment |
Factory Setting |
| Zero=Minimum Current Setting (Imin) |
0 to 0.5 A (for 2 A output version)
0 to 0.3 A (for 1.2 A output model)
0 to 150 mA (for 600 mA output model)
0 to 100 mA (for 400 mA output version) |
0% (CCW) |
| Span=Maximum Current Setting (Imax) |
0.6 to 2.0A* (for 2 A output version)
0.36 to 1.2 A (for 1.2 A output model)
180 to 600 mA (for 600 mA output model)
120 to 400 mA (for 400 mA output version) |
100% (CW) |
| Ramp Time (Rising and Falling Edge) |
0.01 to 5 seconds independent |
minimum (0.01 seconds) (CCW) ** |
| Dither Level (Amplitude) |
0 to 10% of rated maximum current |
0% (CCW) |
| Dither Frequency |
70 to 350 Hz (±10%) |
minimum (CCW) |
CW=clockwise, CCW=counterclockwise
*NOTE 1: Range of maximum output current is 2A (maximum output current=minimum
current setting + maximum current setting).
**NOTE 2: To eliminate ramping, turn the trim pots fully
counterclockwise.
Adjusting the minimum current will shift the maximum
current as shown.
 |
Adjusting the maximum current does not affect the
minimum current setting.
 |
Setting the Minimum Current (Imin)
- Set the minimum current before setting the maximum
current.
- Apply minimum input (control potentiometer at minimum or
0 V or 0 A).
- The factory setting for the Imin trim pot is 0 or fully
counter clockwise (CCW).
- If the desired minimum current is greater than 0,
adjust the trim pot clockwise (CW) until the desired current is
achieved.
The minimum current setting can be used to take into
account the mechanical valve deadband and provide desired offsets from zero to
allow full control within the functional range of the specific valve.
Setting the Maximum Current (Imax)
- Apply maximum control (control pot at maximum or 5 V or
20 mA).
- The factory setting for the Imax trim pot is 100% or
fully CW.
- Turn the trim pot CCW to adjust the current setting
downwards to the desired maximum.
The maximum current setting is adjusted to meet the
customer's working pressure or flow range to the full scale signal input range.
This provides maximum control for a specific application. For example, a 5V
input can represent a 500 mA output (versus a 2A output) if the valve requires
this maximum current for its control function application.
|
Setting the Ramp Times:
- The factory setting for ramp times is the minimum (0.01
seconds) or fully CCW.
- If the ramp time settings are not needed, leave the
setting at the minimum value.
- To change the ramp times, adjust the trim pot CW to
increase the time.
- Note that rising and falling ramp times are
independent.
Ramp times are application dependent. They limit the
rate of change or how fast the operation happens. Note that if the input signal
is not applied long enough for the ramp time set, the desired solenoid current
will not be reached.
|
 |
Setting the Dither Amplitude
- The factory setting for dither amplitude is 0%
(CCW).
- To adjust dither amplitude, turn the trim pot CW until
small changes in the input signal register similar changes in current
output.
- Choose the smallest effective dither amplitude.
Dither amplitude is adjustable from 0 to 10% of the
rated maximum current. Dither amplitude and frequency are dependent on the
specific valve. The effects of static friction on the operation of the solenoid
are reduced by the application of a small AC current. The hysteresis and
repeatability of the valve are improved by this practice. The optimum dither
amplitude is attained when small input signal changes register similar changes
in current output (pressure or flow through the valve).
Setting the Dither Frequency
- The factory setting for dither frequency is the minimum
or 0% (CCW).
- To adjust dither frequency, turn the trim pot CW until
the desired frequency is set.
- Refer to the valve manufacturer's catalogue for the
dither frequency rating of a particular valve.
Troubleshooting:
Diagnostic LED's: Input Level and Output Level green LED's vary in
intensity following the control signal input and output to the valve. Power OK
green LED indicates power supply is connected.
Specifications are subject to update without
notice.
Ordering Part
Numbers:
| PCB Board |
RSD-PCB-5V-x |
| Packaged Driver (board installed in
housing assembly) |
Available with no cable
- RSD-SMB-5V-x-00
Available with 3 connectors
- RSD-SMB-5V-x-01
IP65 rated and available with cable - 5 ft. (1.5m) or 10 ft. (3m)
- RSD-SMB-5V-x-IP5-yM
IP67 rated and available with solid round cable - 5 ft. (1.5m) or 10
ft. (3m)
- RSD-SMB-5V-x-IP7-yM |
| DIN rail mount version (for industrial
control cabinets) |
RSD-DR-5V-x |
| |
Where:
x=maximum current output (2A, 1.2A, 600MA or 400MA)
y=1.5, 3 or custom lengths (meters) |
Other versions are available including
4-20 mA and
0-10 VDC signal input versions as well as a DIN 43650 coil mount version.
|
DATASHEET
Download
the datasheet provided in Adobe PDF format.

If you do not have Adobe Acrobat Reader installed, go to
www.adobe.com
and download Adobe Acrobat Reader. |
Request a fax or
email copy of the datasheet.
Please email sales@axiomatic.com and provide
the product name, part number, your contact information, telephone and fax
number.
|
|