Function:
The Soft Shift Controller introduces a current ramp
permitting the soft start of proportional solenoid valves used for pressure or
flow control in hydraulic circuits. When the unit is powered on, it ramps to
full current output over the ramp on time period that is adjustable within a
factory set range. When the power is switched off, output of the unit falls
immediately to zero. It is available in an IP65 rated DIN 43650 coil mount
version.
Features:
- Cost effective alternative for soft start of
proportional hydraulic circuits
- Broad range of supply voltages (9 to 32 VDC)
- Modern technology utilizing high frequency switching
output (PWM)
- Current output is 650 mA or 2 A (adjustable)
- Current sensing circuit maintains output regardless of
changes in input voltage or coil resistance
- Ramp on time (adjustable)
- Rugged construction to withstand harsh
environments
- IP65 protection class
|
|

The soft shift controller-coil mount connected
to a proportional solenoid valve provides ramp on time.
 |

|
|
Part
Number:
|
|
DIN 43650 coil mount - 2 Amp max., 5
to 10 seconds ramp on time, 250 Hz dither frequency, 2 meter cable -
SSD-H-2-02-2M
|
|
DIN 43650 coil mount - 650 mA
max., 5 to 10 seconds ramp on time, 250 Hz dither frequency, 2 meter cable
- SSD-H-2-02-650MA-2M
|
|
DIN 43650 coil mount - 2 Amp max., 0
to 5 seconds ramp on time, 250 Hz dither frequency, 2 meter cable -
SSD-H-1-02-2M
|
|
DIN 43650 coil mount - 650 mA
max., 0 to 5 seconds ramp on time, 250 Hz dither frequency, 2 meter
cable - SSD-H-1-02-650MA-2M
|
|
Custom ramp times
available.
|
|
Technical
Specifications:
All specifications typical at nominal input voltage and 25
degrees C unless otherwise specified.
General Specifications:
|
Operating conditions
|
-40 to 85°C (-40 to 185°F)
|
|
Storage temperature
|
-50 to 125°C (-58 to 257°F)
|
|
Electrical connection
|
DIN 43650 plug connects to solenoid
coil
Unterminated jacketed cable connects to power supply.
Red (power +) and black (power -), 18 AWG conductors
2 meter cable length is standard (custom lengths available)
Contact the manufacturer for the connection details of
the remote metal box version.
|
|
Protection class
|
DIN 43650 coil mount version:
IP65 when correctly installed with lid, compression washer,
o-ring and base gasket
|
|
Dimensions
|
DIN 43650 coil mount version: see
below
|
|
DIN 43650 coil mount
version:
Dimensions in mm/inches
|
|
Length L1
|
85.35 mm
|
3.36 "
|
|
Length L2
|
61.75 mm
|
2.43 "
|
|
Length L3
|
34.0 mm
|
1.34 "
|
|
Width=L3
|
34.0 mm
|
1.34 "
|
|
Height H1
|
38.0 mm
|
1.49 "
|
|
 |
Electrical Specifications:
|
Operating voltage
|
9 to 32 VDC nominal power supply
range
|
|
Output current range
(adjustable)
|
0.6 to 2.0 A (2A version)
200 to 650 mA (650 mA version)
|
|
Solenoid resistance
|
Rcoil < (Vpower
supply - 1.5V)/Ioutput
|
|
Ramp on time
|
Increasing - 0.01 to 5 seconds or 5 to 10
seconds
or customer specified range
|
|
Dither amplitude
|
10 % of maximum rated current (fixed)
|
|
Dither frequency
|
250 Hz (fixed) +/- 10%
|
* Note 1: Match power supply voltage with
rating of solenoid coil. Operating the controller with a supply voltage lower
than the solenoid rated voltage may result in reduced current output. The
current output of the controller should not exceed the current rating of the
solenoid coil.
Note 2: The coil should have no polarity or protection diodes for proper
operation of the device.
Adjustments:
 |
Use a small screwdriver to loosen the mounting screw
and remove the transparent lid. The single turn trim pots are adjusted with a
Phillips #0 sized screwdriver.
|
|
Trim Pot Adjustments
Trim pots are single turn.
|
Range of Adjustment
|
Factory Setting
|
|
Output Current Setting
|
0.6 to 2.0A (2A version)
200 to 650 mA (650 mA version)
|
Minimum (CCW)
|
|
Ramp On Time
|
0.01 to 5 seconds
or 5 to 10 seconds
or customer specified range
|
Maximum (CW)
|
Mounting:
1. Ensure the lid, compression washer, o-ring and base gasket are correctly in
place (necessary for IP65 protection).
2. Ensure that no damage or injury can occur on the machine when the valve is
operated.
3. Attach the soft shift controller to the load and tighten the mounting screw.
4. Connect the cable to the power supply (red is power +, black is power -).
5. Switch on the power supply to the soft shift controller.
6. Adjust the current output and ramp on time to suit the application.
Specifications are subject to update without
notice.
OEM and distributor pricing is available upon
request.
|
DATASHEET
For technical specifications download the Datasheetprovided in Adobe PDF format.
To request a faxed copy of the datasheet
please email sales@axiomatic.com and provide
the product name, part number, your contact information, telephone and fax
number.
|
Double click on the pdf icon to link
to Technical Data.
Technical Data
If you do not have Adobe Acrobat Reader installed,
go to www.adobe.comand
download Adobe Acrobat Reader.
|
|