Part No.:
Connector Amplifier
CAPVE-H-4-20MA-2A-4C-2M
Function:
The Connector Amplifier - coil mount supplies a solenoid valve with current
proportional to an input control (4-20 mA).
Application:
Accurate control of hydraulic and pneumatic proportional solenoid valves used
in mobile equipment and industrial hydraulic or pneumatic circuits.
|
|
|
Description:
The economy version of the Connector Amplifier simplifies control of
proportional solenoids by supplying a current proportional to an input control
(4-20 mA). It accepts power supply voltages from 9 to 32 VDC. This linear
solenoid controller utilizes high frequency switching output (PWM) to provide a
DC current output. Maximum current output is 2 Amps. A current sensing circuit
maintains current output regardless of changes in input voltage or coil
resistance. The user can adjust maximum and minimum current. Dither frequency
and amplitude are factory set to 250 Hz. In this economy version of the
connector amplifier there are no ramps. The unit is available with a DIN 43650
connection to mount directly on the coil and comes complete with 2 meters of
unterminated cable.
|
 |
|
Features:
- Accepts 4-20 mA control signal input
- Maximum current output of 2 Amps
- Mates to a DIN 43650 plug on a cartridge or block style
solenoid valve
- Broad range of supply voltages (9 to 32 VDC) with no
degradation in performance
- Current sensing circuit maintains output regardless of
changes in input voltage or coil resistance
- Modern technology utilizing high frequency switching
output (PWM)
- Dither frequency and amplitude are factory set at 250 Hz
and 5%
- Maximum current adjustment does not affect minimum
current setting
- Adjustments accessible with a removable cover
- IP65 weather resistance rating
- Energy efficient design (no heat sink is
required)
- Electronic limiting circuit means no internal
fuses
- Short circuit proof (in case of solenoid failure or
miswiring)
- Reverse polarity protection
- CE certified
- Can disconnect load while connector amplifier is powered
("Hot Swap")
|
Technical Specifications: All specifications
typical at nominal input voltage and 25 degrees C unless otherwise specified.
|
General Specifications:
|
| Operating
conditions |
-40 to + 85°C (-40 to 185°F)
0 to 85% relative humidity |
| Storage
temperature |
-50 to 125°C (-58 to 257°F)
|
| Electromagnetic
compatibility (EMC) |
Emission EN 50081-2
Immunity EN 50082-2 |
| Approvals |
CE |
| Electrical
connection |
DIN 43650 plug
2 metres jacketed cable, 4 conductor (18 AWG) |
| Protection
class |
IP65 when correctly installed with lid,
compression washer, o-ring, and base gasket |
|
Dimensions in mm/inches |
Length L1
L2
L3
Width=L3
Height H1 |
85.35 mm
61.75 mm
34.00 mm
34.00 mm
38.00 mm |
3.36"
2.43"
1.34"
1.34"
1.49" |
|
 |
|
Electrical Specifications:
|
Operating
voltage*
(power supply requirement) |
9 to 32 VDC
nominal power supply range |
| Control input
signal options |
4-20 mA
current signal |
| Range of
maximum output current* |
2
A |
| Response
time |
<10 mSec.
|
| Input
resistance |
50
Ohms |
| Solenoid
resistance selection (nominal) |
Rcoil<(Vpower supply -
1.5V)/Imax |
| Current dither
frequency (fixed) |
250 Hz (+/-
10% of full scale) |
| Dither
amplitude (fixed) |
5 % of rated
maximum current |
| Minimum current
(adjustable) |
0 to 500
mA(single turn trim pot) |
| Maximum current
(adjustable)* |
600 to 2000
mA (single turn trim pot) |
* Note:
- Match power supply voltage with rating of solenoid coil.
Operating the amplifier with a supply voltage lower than the solenoid rated
voltage may result in reduced maximum current output.
- The coil should have no polarity or protection diodes
for proper operation of the device.
- Do not exceed the current rating of the solenoid coil
with the maximum current output of the driver.
- Range of maximum output current is 2A (maximum output
current=minimum current setting + maximum current setting).
The single turn trim pots are adjusted with a Phillips#0 screwdriver.
Mounting Instructions:
- Supply voltage should be between 9 and 32 VDC. Excess
voltage will damage the unit. Match the power supply voltage with the voltage
rating of the solenoid coil. Operating the amplifier with a supply voltage
lower than the solenoid rated voltage may result in reduced maximum current
output.
- The coil should have no polarity or protection diodes
for proper operation of the device.
- Do not exceed the current rating of the solenoid coil
with the maximum current output of the driver.
- Do not install the amplifier near high voltage relays or
other sources of electrical interference.
- Connect the power supply, signal input and valve
solenoid.
- Set the input signal to the maximum level and confirm it
is operating properly.
- Ensure the transparent lid is firmly in place. Ensure
the brown rubber base gasket is in place, providing a seal between the
amplifier and the plug on the valve. The mounting screw, compression washer and
o-ring should be flush with the top of the lid and fastened in place.
- Tighten the screw to make a firm connection to the valve
with a Phillips #2 screwdriver.
Connections:
Connect the cable conductors to the power supply and input signal as follows.
For 4-20 mA Control:
Use I-Min. screw to set up minimum speed with minimum control input.
Use I-Max. screw to set maximum speed with 100% of control input.

For wiring diagrams, request a faxed copy
of the datasheet.
Adjustments:

Adjusting the minimum current will shift the maximum
current as shown.
 |
Adjusting the maximum current does not affect the
minimum current setting.
 |
Setting the Minimum Current (Imin):
- Set the minimum current before setting the maximum
current.
- Apply minimum input (4 mA).
- The factory setting for the Imin trim pot is 0 or fully
counter clockwise (CCW).
- If the desired minimum current is greater than 0, adjust
the trim pot clockwise (CW) until the desired current is achieved.
The minimum current setting can be used to take into
account the mechanical valve deadband and provide desired offsets from zero to
allow full control within the functional range of the specific valve.
Setting the Maximum Current (Imax):
- Apply maximum control (20 mA).
- The factory setting for the Imax trim pot is 100% or
fully CW.
- Turn the trim pot CCW to adjust the current setting
downwards to the desired maximum.
The maximum current setting is adjusted to meet the
customer's working pressure or flow range to the full scale signal input range.
This provides maximum control for a specific application.
|
Ordering Part Number:
|
Connector Amplifier
(Economy Version)
DIN 43650 coil mount version - 4-20 mA input, 2 Amp max. output - 2 m cable
- P/N: CAPVE-H-4-20MA-2A-4C-2M
- Custom cable lengths are available. |
OEM and distributor pricing is available upon
request.
|
DATASHEET
Download
the datasheet provided in Adobe PDF format.

If you do not have Adobe Acrobat Reader installed, go to
www.adobe.com
and download Adobe Acrobat Reader. |
Request a fax or
email copy of the datasheet.
Please email sales@axiomatic.com and provide
the product name, part number, your contact information, telephone and fax
number.
|
Specifications are subject to update without
notice.
|