AX03054X: 4 Analog or PWM Signal Output Controller (SAE J1939 or CANopen®)
The 4 Analog or PWM Signal Output CAN Controller can extend machine control networks by adding I/O to the CAN bus. Engine control systems with SAE J1939 or CANopen® can communicate with 4-20 mA or other signal input devices using this controller as a smart interface. The Axiomatic controller can be configured to suit the specific application using a service tool. User selectable outputs include: 0-5V; 0-10V; +/-5V; +/-10V; 0-20mA; 4-20 mA; and +/-20mA. Alternatively, PWM signal outputs can be selected. The controller comes in two models, the AX030540 for SAE J1939 networks or the AX030541 for CANopen® applications.
4 independent analog signal or PWM outputs, selectable from:
standard analog voltage signal ranges, including: 0-5V; 0-10V; +/-
5V; +/-10V with maximum 25mA load
Analog current signal ranges, including: 0-20mA; 4-20 mA; and
+/-20mA with maximum 500Ω load
PWM outputs, including: PWM 0-100% D.C.; and Frequency 0.5-
30 kHz (5V or 12V Amplitude, maximum 40mA load)
Control logic:
Standard embedded software
Communications:
AX030540: SAE J1939, Auto-baud-rate-detection
AX030541:CANopen®
User Configurability:
AX030540: Electronic Assistant, P/N: AX070502
AX030541: Commercially available CANopen® tools.
Enclosure:
High Temperature Nylon housing
24-pin connector
TE Deutsch PCB Enclosure (EEC-325X4B)
4.62 x 5.24 x 1.43 inches
117.42 x 133.09 x 36.36 mm
(WxLxH excluding mating plug)
Protection Rating:
IP67
Operating Conditions:
-40 to 85°C (-40 to 185°F)
PDF Datasheet:
Click icon for PDF datasheet (AX030540). Click icon for PDF datasheet (AX030541).
This is a unique website which will require a more modern browser to work!