The CAN-PWM Signal Converter features PWM Signal output to communicate with an engine ECM; output is user configurable as Frequency or digital. This product meets the surge requirements of SAE J1445, and is designed for EMC compliance, and is configurable with Axiomatic Electronic Assistant.
P/N: AX130700 (CAN-PWM Signal Converter, 1 SAE J1939)
Power:
12 V or 24 Vdc nominal
Output:
PWM Signal, Frequency Signal or Mixed Output
1 Hz to 20 kHz
0-100% D.C. (User configurable)
5V or 12V amplitude
Push pull output
Maximum load is 50 mA (at 5V) or 30 mA (at 12V).
Over-current protection (50 mA)
Digital Level
Digital On/Off
5V or 12V Amplitude
Maximum load is 50 mA (at 5V) or 30 mA (at 12V)
Control Logic:
The CAN-PWM Signal Converter comes pre-programmed with standard logic.
User Interface:
Electronic Assistant AX070502
Communications:
1 CAN (SAE J1939) with auto-baud-rate-detection
Electrical Connections:
6 pin TE Deutsch connector P/N: DT04-6P
Enclosure:
Plastic Enclosure, Nylon 6-6 with 30% glass fill
Integral Deutsch IPD connector
3.030 x 2.413 x 1.314 in
77.0 x 61.3 x 33.4 mm (L X W X H)
Protection Rating:
IP67
Operating Conditions:
-40 to 85°C (-40 to 185°F)
PDF Datasheet:
Click icon for PDF datasheet.
This is a unique website which will require a more modern browser to work!