AX130751: CAN to 2 Analog/Digital Signals and 1 Relay Output Converter
The CAN to 2 Analog/Digital and 1 Relay Outputs Converter features 2 Analog/Digital signal outputs configurable as: 0-5V; 0-10V; 4-20 mA; Frequency or PWM Signal as well as 1 Relay output. Networking is via 1 isolated CANopen® port. It is Operational 9…36 Vdc (12 Vdc or 24 Vdc). The controller meets the surge requirements of SAE J1445, and is designed for EMC compliance for engine applications.
CAN to 2 Analog/Digital Signals and 1 Relay Output Converter
CANopen®
Order Code:
P/N: AX130751 (CAN to A/D and Relay Outputs Converter, CANopen®)
Power:
12 V or 24 Vdc nominal; 9…36 Vdc
The minimum allowable supply voltage for the power pin is 7 Vdc.
Signal Outputs:
2 Analog/Digital signal outputs configurable as: 0-5V; 0-10V; 4-
20 mA; Frequency or PWM Signal.
Relay Output:
1 Relay Output
Control Logic:
Standard embedded control logic
User Interface:
EDS File, Standard CANopen tools (not supplied)
Communications:
1 CANopen®
Electrical Connections:
Integral TE Deutsch 12 pin receptacle (P/N: DTM04-12PA)
Enclosure:
Molded Enclosure, integral connector
Nylon 6/6, 30% glass
Ultrasonically welded
3.54 x 2.75 x 1.31 inches (90.09 x 70.00 x 33.35 mm)
L x W x H including integral connector
Protection Rating:
IP67
Operating Conditions:
-40 to 85°C (-40 to 185°F)
PDF Datasheet:
Click icon for PDF datasheet.
This is a unique website which will require a more modern browser to work!