Two universal signal inputs are configurable as: Voltage, Current, PWM, Digital or Resistive (for Input 1 only). The Thermocouple Module also monitors 1 channel of Type J, K, B, E, N, R, S or T thermocouples. The temperature information is provided to the engine control system over an isolated SAE J1939 CAN bus. Temperature information can include exhaust temperature, winding temperature, and fluid temperature monitoring. All channels are fully isolated. Temperature data is automatically sent over the CAN bus when power is applied. The input is isolated. Integral diagnostics can flag open wire fault detection. The product enclosure is rated as IP67 and has a 12 pin Deutsch style connector.
12V, 24V or 48Vdc nominal (9…60Vdc power supply range)
TC Input:
One (1) Type J, K, B, E, N, R, S or T
Signal Inputs:
2 Universal Signal Inputs configurable as: Voltage, Current, PWM, Digital or Resistive (for Input
1 only)
Control logic:
Pre-programmed with standard logic. Refer to the user manual.
Communications:
2 Isolated CAN ports (SAE J1939)
Electrical Connections:
Integral TE Deutsch 12 pin receptacle
Enclosure:
Molded Enclosure, integral connector
Nylon 6/6, 30% glass
Ultrasonically welded
3.54 x 2.75 x 1.31 inches (90.09 x 70.00 x 33.35 mm)
L x W x H including integral connector
Protection Rating:
IP67
Operating Conditions:
-40 to 70°C (-40 to 158°F)