The 1 Analog signal input CAN controller belongs to a family of Axiomatic smart controllers with programmable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality.
The 1 signal input (V/I/PWM) to CAN Converter features 1 voltage, current or PWM signal input. The signal input is user selectable input range from: 0-5V; 0-10V; 0-20mA; 4-10mA; 0.5Hz-50Hz; 10Hz-1kHz; or 100Hz-10 kHz. It meets the environmental and electrical requirements of SAE J1445 and SAE J1113-11. Communication protocols are CAN SAE J1939 or CANopen®.
The 1 Universal Input CAN Controller belongs to a family of Axiomatic smart controllers with programmable internal architecture. This provides users with flexibility, allowing them to build their own custom controller with a required functionality from a set of predefined internal functional blocks using the CAN interface.
The 10 Universal Signal Input Module accepts up to 10 analog or digital type inputs (0- 5V, 0-10V, 0-20 mA, 4-20 mA, Digital, PWM, Frequency/RPM, or Counter). The modules can be connected to a variety of analog machine sensors or levers, PLCs, switches, PWM signals, etc. It interfaces with the machine’s CAN network (SAE J1939 or CANopen®). Standard embedded software is provided. Rugged packagin...
The 11 Input to 9 Output CAN Controller takes 12VDC or 24VDC nominal inputs with surge and transient protection. The unit features reverse polarity, overvoltage, undervoltage and short circuit protections, alongside input and output isolation. The controller belongs to a family of Axiomatic smart controllers with configurable internal architecture. This provides users with flexibility, allowing...
The 12 Channel Strain Gauge CAN controller accepts up to twelve 4-wire strain gauge connections. The input range is user selectable from +/- 2.5 mV to +/- 2.5 Vdc. The measurement rate is 1000 scans per second for all 12 channels. It interfaces with the machine’s CAN network. Two CAN ports are provided. The measurement rate and the update rate are high speed for all channels. Standard embedded s...
The 18 Digital Signal Input Module accepts up to 10 digital type inputs (Active High/Active Low, digital, disabled PWM signal, Frequency, or counter). Up to 8 additional digital inputs are user selectable as Active High or Active Low. The electronic control can be connected to a variety of machine switches, sensors, PWM signals, etc. It interfaces with the machine’s CAN network (SAE J1939 or CAN...
The 2 Bipolar Analog/Digital and 8 Universal Signal Inputs Controller features a Modbus TCP/IP port and a CAN port. It has two reference voltages (+5V), and two LED indicators. The controller is configurable via CAN interface.
The 2 Bipolar Analog/Digital and 8 Universal Signal Inputs Controller features an SAE J1939 CAN port with auto-baud-rate detection. It has two reference voltages (+5V), and two LED indicators. The controller is configurable via the Axiomatic Electronic Assistant.
The 12 Inputs, 8 Analog and 1 Relay Outputs CAN I/O Module can extend machine control networks by adding I/O to the CAN bus. The controller features 1 Isolated CAN port for user-defined communications over the bus. It accepts up to 10 analog (0-5 V, 0-10 V, 0-20 mA or 4-20 mA), digital, PWM, pulse (frequency or RPM), or counter inputs. Two voltage references (user configurable as +5 or +10 V) ar...
The 3 Encoder, 7 Signal Inputs CAN Controller accepts up to 3 encoder inputs, 1 analog or digital input (0-5V, 0-10V, 0-20 mA, 4-20 mA, digital, PWM, frequency/RPM, or counter), 4 digital inputs (digital, PWM, frequency/RPM), and 2 digital inputs. Rugged IP67 rated enclosure, in addition to a wide-ranging power supply input section for 12V, 24V, or 48Vdc power, suits the harsh environment applicat...
The 4 Signal Outputs CAN Controllers can extend machine control networks by adding outputs to the CAN bus. Engine control systems with SAE J1939 or CANopen® can communicate with other signal input devices using these controllers as a smart interface. The controllers can be configured to suit the specific application using CAN interface. Depending on the model, the users can select outputs from th...
The 4 Channel Strain Gauge CAN controller with Wire Break Detection accepts up to four 4-wire strain gauge connections. The input range is user selectable from +/-19.5 mV to +/-2.5 V. It interfaces with the machine’s CAN network (SAE J1939 or CANopen®). The measurement rate is up to 40,000 samples per second (SPS). Standard embedded software is provided. Rugged IP67 rated enclosure and a power ...
These controllers feature 4 universal inputs configurable as voltage, current, resistive, frequency, PWM, or digital. They need a 12 or 24 VDC nominal input (8 to 36 VDC range) to operate and communicates through a CAN network (SAE J1939 or CANopen®). Users can select a +5V or +8V reference. The units have compact IP67 enclosures and integral TE Deutsch equivalent connectors. The controllers are ...
The controller accepts 4 AC voltage or current inputs. It is connected to the CAN bus. Power is 12V or 24Vdc nominal. Up to 4 analog signal outputs are user selectable from the following: 0-5Vdc, 0-10Vdc, +/-5Vdc, +/-10Vdc, 4-20 mA, or 0-20mA. LEDs indicate operational status. The enclosure is DIN rail mount. It operates from -40 to 85°C (-40 to 185°F). Standard embedded software is provided and...
These Current to Current Converters accept a 24Vdc power supply (nominal) and a 4-20mA input signal converting it to a current output. Various outputs are available depending on the model, including 0-50 mA, 0-100 mA, 0-160 mA, 20-160 mA, 40- 160 mA, 0-200 mA, 20-200 mA, or bipolar (10-310 mA) . Span and zero is user adjustable. The load should be floating, isolated from ground. Diagnostic LEDs in...
The 6 Digital Input Controller with Dual CAN Controller is designed to accept digital inputs and transmit data to a CAN Network. All 6 inputs are selectable to read frequency, PWM, or digital signals. The device provides configurable settings, allowing users to create custom configurations. The unit is in a compact IP67 enclosure and operates from -40°C to +85°C.
The Bipolar Input, Relay and Analog Signal Output Controller features 1 isolated CAN port. It has 1 universal signal input (bipolar or unipolar voltage, current, digital, PWM, or frequency type), 1 Form C NC relay output, and 1 analog output (0-5V, -10V, 0-20mA, or 4-20mA). A Near Field Communication (NFC) antenna is provided for simple configuration using an Android smartphone or device.
The CAN to 1 Signal Output Controller features 1 output configurable as 0-5V, 0-10V, +/-5V, +/-10V, 0-20 mA, 4-20 mA, or PWM. Networking is via 1 CAN port. It is operational from 9 to 36 Vdc (12 or 24 Vdc). All parameters are configurable over CAN.
The CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converter features 2 analog/digital signal outputs configurable as 0-5V, 0-10V, 0-20 mA, 4-20 mA, frequency, or PWM Signal as well as 1 relay output. Communication is over 1 isolated SAE J1939 or CANopen® port. It is operational 9…36 Vdc (12 Vdc or 24 Vdc). The Converter meets the surge requirements of SAE J1445 and is designed for...
The CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converter features 2 analog/digital signal outputs configurable as 0-5V, 0-10V, 0-20 mA, 4-20 mA, frequency, or PWM Signal as well as 1 relay output. Communication is over 1 isolated SAE J1939 or CANopen® port. It is operational 9…36 Vdc (12 Vdc or 24 Vdc). The Converter meets the surge requirements of SAE J1445 and is designed for...
The CAN to PWM Signal Controller features 1 PWM signal output to communicate with an engine ECM. The output is user configurable as PWM, frequency, or digital. This product meets the surge requirements of SAE J1445 and is designed for EMC compliance. It has 1 isolated CAN port to read engine speed messages or other engine information.
These I/O Modules have signal inputs and/or outputs as well as one or more relay outputs. AX031800, AX031801, AX031850, AX031850-01, AX031850-02, and AX031851 read 12 discrete inputs and set 8 Form C relay outputs while networking with other CAN devices (SAE J1939 or CANopen®) in a machine control system. The units are battery powered with the ability to withstand engine cranking, reverse pola...
The Isolated Dual Channel Universal Signal CAN Converter accepts 2 universal signal inputs (voltage, current, resistive, PWM, frequency/RPM, or digital). Additionally, 1 magnetic pick up sensor and 1 encoder input is also supported. It provides 2 signal outputs (voltage, current, PWM, frequency, mixed, or digital). The unit can network with engine control system over CAN bus. The unit has 4-way is...
The Economy Dual Channel Universal Signal Converter accepts two voltage, current, resistive, frequency, RPM, PWM, or digital control signal inputs and converts them into two signal outputs (voltage, current, frequency, PWM, mixed, or digital). A +5V reference powers sensor inputs. The control can be connected to a CAN (SAE J1939 or CANopen®) networked engine control system.
The Isolated Dual Channel Universal Signal Converter with CAN accepts 2 inputs (voltage, current, resistive, PWM, frequency/RPM, or digital) and converts them into 2 signal outputs (voltage, current, PWM, frequency, mixed, or digital). A +5V reference powers sensor inputs. The unit has 4-way isolation between power, inputs, outputs, and CAN. The unit communicates over CAN (SAE J1939 or CANopen®...
This 4 Digital Inputs Controller features an Ethernet port, a CAN port, and 4 Digital signal inputs. It offers IP67 protection and is configurable via CAN interface or via Ethernet.
The 1 Digital Input, 2 Relay Outputs Controller features 1 Isolated CAN port and 2 Form C relay outputs. Plug and play option is available, along with programmable logic.
The LVDT/RVDT Simulator is used to test LVDT (Linear Variable Differential Transformer) or RVDT (Rotary Variable Differential Transformer) sensors. Using a 0- 10VDC command signal input and an excitation (drive input), the unit provides two simulation outputs of 1-5VAC. An internal 3kHz oscillator can be used as an alternative excitation source. Both outputs are fully isolated. The unit accepts...
The Magnetic Pickup Input to CAN Converter transforms a magnetic speed sensor signal into CAN (SAE J1939 or CANopen®) messages for communication with control systems. It comes in a compact, fully sealed enclosure with IP67 protection rating. It can be configured via CAN interface.
The Cell Battery Voltage Monitors interface to monitor voltage levels of cells in a battery and are suitable for most battery chemistries. They use 12V or 24Vdc nominal input power and come with rugged surge protection. They feature IP67 protection. User configuration is via CAN interface.
The PWM to Current Signal Converters provide a compact DIN rail mount solution for converting a digital PWM (Pulse Width Modulation) signal into a current signal. Isolation varies depending on the model.
The PWM to Voltage Signal Converters provide a compact DIN rail mount solution for converting a digital PWM (Pulse Width Modulation) signal into a voltage signal. Isolation varies depending on the model.
The RS-232 to CAN Converter with Two Digital Inputs is a compact device for interfacing RS-232 satellite phones or GPS systems with CAN bus in on-road commercial vehicles. The RS-232 serial port interface is provided with user-configurable frame forwarding system to convert serial port messages into CAN frames. Likewise, the two fully isolated CAN interfaces have user-configurable CAN ID filter...
The Universal Signal Converter offers three-way isolation and translates 1 input control signal into 3 simultaneous outputs. Its switches allow the user to select the desired input and output(s). One of PWM, voltage, or current signal input is accepted while 3 PWM, voltage, and current outputs are simultaneously available. Span and zero adjust with multi-turn pots for both voltage and current o...
The Voltage to Bipolar Current Converters accept 24 VDC power supply (nominal). A voltage input signal is converted to a bipolar current output. Span and zero is user adjustable. The load can be floating or grounded. Diagnostic LEDs indicate power and operational status. The PCB is conformal coated. The unit is available in a DIN rail mount enclosure.
The Voltage or Current to PWM Signal Converters provide a compact DIN rail mount solution for converting a voltage signal into a digital PWM (Pulse Width Modulation) signal. Isolation varies depending on the model.
The wake-on-charge module manages the vehicle controller power mode for wake and sleep. It has a charger status indication when the vehicle is plugged in (on-charge). It features a CAN 2.0B port. It performs the following functions.
The 1 Input, 1 Output, Isolated Signal Converter is designed to accept various types of inputs and convert the data into different types of outputs, while transmitting data over a CAN network. The input is configurable to measure voltage, current, resistive, frequency, PWM, or digital input signals. The device is able to produce a variety of outputs including voltage, current, frequency, PWM, or d...
This controller has 2 isolated CAN ports. The signal output is configurable as Sine or Square wave (0-5V). It also provides a PWM output signal. The control has a rugged IP67 enclosure and connector.
The 1 Resistive Output CAN Controller is designed to emulate an analog joystick or a potentiometer. It can be used as an interfacing module for CAN-based engine control or machine control units. It delivers 1 resistive output of up to 5000 Ohm (with 3 terminals) which can be configured. The hardware supports 1 CAN port. Numerous configurable variables have been provided which are accessible over C...
The 12 Signal Outputs Controllers provide 12 analog or digital type outputs (0-5 V, 0-10 V, +/- 5 V, +/- 10 V, 0-20 mA, 4-20 mA, +/- 20 mA, Frequency, PWM, or Digital On/Off). The controllers interface with the machine’s CAN network (CANopen® or SAE J1939). A rugged IP67 rated TE Deutsch enclosure and a wide-ranging power supply input section for 12, 24, or 48 VDC makes the controllers suitable...
The isolated current converters accept a 24 VDC nominal power supply (operating from 9 to 45 VDC). A diagnostic LED indicates power and operational status. The output LED is on when the load, input signal, and power supply are connected. The LED flashes when the load is disconnected. The load can be floating or grounded. Span and zero are user adjustable. The isolated current converter units are a...
The interface modules accept 16 universal signal inputs and generate 12 universal signal outputs, 2 high side digital outputs, and 1 PWM digital output. The interface devices in this category communicate with CAN bus and Ethernet devices. The modules operate with an input voltage of 12, 24, or 48 VDC nominal (6 to 58 VDC). The controllers are rated IP67 ensuring efficient operation in moist and vi...
The LED output CAN controllers supports independent LED outputs and offer dual control modes, allowing for direct current (DC) operation and pulse-width modulation (PWM). The dual control modes provide steady illumination and dimming/dynamic lighting effects. The controllers are built on the reliable CAN bus protocol, ensuring seamless integration into existing vehicle and machine communication ne...
The Universal Signal Converters feature a variety of different inputs and outputs. The controllers need a 12 or 24 VDC nominal input (8 to 36 VDC range) to operate and communicate through a CAN network. The universal signal converters are configurable via standard CAN interface tools. The units are available with a DIN rail mount enclosure or a TE Deutsch high temperature nylon PCB enclosure depen...
We offer fresh design ideas and rapid prototyping that caters to the needs of OEM’s from different industries relying on battery-powered control systems. Contact us for customization or new product design.
Tell Us Your RequirementsAutomation
Power Management
Connectivity Solutions
Machine Control
Accessories