12 Inputs, 12 Proportional & 2 Relay Outputs Controller, 2 SAE J1939
Item # AX021400 — 12 Inputs, 12 Proportional & 2 Relay Outputs Controller, 2 SAE J1939
The 12 input, 14 output controller accepts 8 universal signal inputs, 1 additional digital input, 1 magnetic input, 1 encoder input, and 1 wake input (used for Wake-on-CAN functionality). AX021400 generates 12 programmable proportional outputs and 2 relay outputs (2 A maximum) while networking with other CAN devices. The device features 2 CAN 2.0B ports (SAE J1939 and CAN-FD compliant) and 1 Ethernet port (for configuration purposes only). The module operates with an input voltage of 24 VDC nominal (9 to 36 VDC). The AX021400 unit features an IP67-rated enclosure ensuring it is suitable for humid and high vibration environments such as off-highway equipment and industrial automation.
Our products are designed to be customized by our customers and can be thought of as product foundations. Find the foundational product(s) that you need in our catalog, add them to your quote cart, then explain your requirements for your project on the quote cart submission form. If you cannot find the foundational product, please tell us your requirements.
Technical Specifications
12 Inputs, 12 Proportional & 2 Relay Outputs Controller, 2 SAE J1939, Ethernet
Order Code
P/N: AX021400
Input(s)
1 magnetic pick-up input (0.5 Hz to 10 kHz)
1 encoder input (0-5 V)
1 wake input, used for Wake-on-CAN functionality
8 signal inputs user selectable as follows:
Voltage (0-5 V, 0-10 V)
Current (0-20 mA, 4-20 mA)
Resistive (10-250 kΩ)
Frequency/RPM (0.1 Hz to 10 kHz)
PWM (0.1 Hz to 10 kHz)
Counter (0-250,000 pulses)
Digital (0-5 V)
1 additional digital input selectable as frequency/RPM, PWM, counter, or digital.
Output(s)
2 relay outputs (30 V max., 2 A max.)
12 proportional outputs programmable as follows:
Voltage (0-36 V)
Current (up to 2.5 A)
Frequency (150 Hz to 250 kHz)
PWM (150 Hz to 250 kHz)
Digital
CAN Port(s)
2 SAE J1939 ports
Wake-on-CAN functionality for power saving
*CAN-FD support may be available upon request.
CAN Baud Rate
250 kbit/s, 500 kbit/s, 667 kbit/s, and 1 Mbit/s with auto-baud-rate detection
Ethernet Port(s)
1 Ethernet TCP/IP port for configuration
10/100 Mbps
Operating Voltage
24 VDC nominal (9-36 VDC)
Control Logic
Standard embedded logic is provided.
Device functionality is user programmable.
Enclosure
Infino SC-1220UR
Polycarbonate, gasket
Flammability rating: UL 94-V2
Connection(s)
1 4-pin M12 female connector (D-coded), Binder P/N: 99-3732-201-04
10 6-pin male connectors, equivalent to TE Deutsch P/N: DT15-6P
Protection Rating
IP67
Operating Temperature
-40 to 85 ºC
-40 to 185 ºF
User Interface
The user configurable functionality is accessible via web server
Applications
Industrial automation
Off-highway equipment
Accessories
AX070119, Mating Plug Kit (DT06-6S, W6S, 6 Contacts)
Datasheet
User Manual
2D Drawing
Related Products
12 Inputs, 8 Relay Outputs Module, SAE J1939, 1 Mbps, LED Indicator
12 Inputs, 8 Relay Outputs Module, SAE J1939, 500 kbps, LED Indicator
12 Signal Inputs, 18 Outputs Controller, SAE J1939, DIN Rail
12 Inputs, 8 Analog and 1 Relay Output I/O Module, SAE J1939, 1 Mbps
12 Inputs, 8 Analog and 1 Relay Output I/O Module, SAE J1939, 500 kbps
1 Digital Input, 2 Relay Outputs Controller, SAE J1939, 1 Mbps, DIN Rail
1 Digital Input, 2 Relay Outputs Controller, SAE J1939, 500 kbps, DIN Rail
1 Digital Input, 2 Relay Outputs Controller, SAE J1939, 250 kbps, DIN Rail
1 Relay & 2 Universal Outputs Controller, SAE J1939
0-5VDC to 4-20mA Signal Converter, +5V Reference
4 Magnetic Pickup Inputs CAN Converter, CANopen®
21 Inputs, 4 Analog & 2 Relay Outputs Isolated Controller, 2x CANopen®
10 Universal Signal Input Controller, +5V Reference, CANopen®
10 Universal Signal Inputs Controller, +5V Reference, SAE J1939
1 Digital Input, 2 Analog Outputs, 2.5A H-Bridge Controller, CANopen®
Automation
Power Management
Connectivity Solutions
Machine Control
Accessories
The 12 VDC input power converters operate from a 12 VDC (nominal) battery or other source and provide a clean VDC output power suitable for instrumentation and control networks equipment. For operation under harsh and demanding conditions, the units are fully sealed to protect against moisture, shock, and vibration. Each power converter unit in this category is designed with rugged electrical protections. Nominal nameplate ratings will vary.
View All