12 Inputs, 12 Proportional & 2 Relay Outputs Controller, 2 SAE J1939, Ethernet
Item # AX021400 — 12 Inputs, 12 Proportional & 2 Relay Outputs Controller, 2 SAE J1939, Ethernet
The 12 input, 14 output controller accepts 8 universal signal inputs, 1 additional digital input, 1 magnetic input, 1 encoder input, and 1 wake input (used for Wake-on-CAN functionality). AX021400 generates 12 programmable proportional outputs and 2 relay outputs (2 A maximum) while networking with other CAN and Ethernet devices. The device features 1 Ethernet port (10 or 100 Mbit/s) and 2 CAN 2.0B ports (SAE J1939 and CAN-FD compliant). The module operates with an input voltage of 24 VDC nominal (9 to 36 VDC). The AX021400 unit features a compact, IP67 rated enclosure ensuring it is suitable for humid and high vibration environments such as off-highway equipment and industrial automation.
Note: This product is under development. Its technical specifications may be subject to change.
Our products are designed to be customized by our customers and can be thought of as product foundations. Find the foundational product(s) that you need in our catalog, add them to your quote cart, then explain your requirements for your project on the quote cart submission form. If you cannot find the foundational product, please tell us your requirements.
The 12 input, 14 output controller accepts 8 universal signal inputs, 1 additional digital input, 1 magnetic input, 1 encoder input, and 1 wake input (used for Wake-on-CAN functionality). AX021400 generates 12 programmable proportional outputs and 2 relay outputs (2 A maximum) while networking with other CAN and Ethernet devices. The device features 1 Ethernet port (10 or 100 Mbit/s) and 2 CAN 2.0B ports (SAE J1939 and CAN-FD compliant). The module operates with an input voltage of 24 VDC nominal (9 to 36 VDC). The AX021400 unit features a compact, IP67 rated enclosure ensuring it is suitable for humid and high vibration environments such as off-highway equipment and industrial automation.
Note: This product is under development. Its technical specifications may be subject to change.
Technical Specifications
12 Inputs, 12 Proportional & 2 Relay Outputs Controller, 2 SAE J1939, Ethernet
Order Code
P/N: AX021400
Input(s)
8 signal inputs user selectable as follows:
Voltage
Current
Resistive
Frequency
PWM
Digital
1 additional digital input
1 magnetic input
1 encoder input
1 wake input, used for Wake-on-CAN functionality
Output(s)
12 proportional outputs programmable as follows:
Voltage
Current
Frequency
PWM
Digital
2 relay outputs
Communications
1 Ethernet port (10/100 Mbps)
2 CAN ports (SAE J1939, CAN-FD)
CAN Port(s)
2 CAN 2.0B ports (SAE J1939, CAN-FD)
Wake-on-CAN functionality for power saving
CAN Baud Rate
250 kbit/s, 500 kbit/s, 667 kbit/s, or 1 Mbit/s with auto-baud-rate detection
Ethernet Port(s)
1 port (10/100 Mbps)
Operating Voltage
24 VDC nominal (9-36 VDC)
Control Logic
Standard embedded software is provided.
User programmable functionality using the Electronic Assistant (EA),
P/N: AX070502 or P/N: AX070506K
Enclosure
Infino SC-1220UR
Polycarbonate, gasket
Flammability rating: UL 94-V2
Connection(s)
1 4-pin M12 female connector (D-coded), Binder P/N: 99-3732-201-04
10 6-pin male connectors, equivalent to TE Deutsch P/N: DT15-6P
Protection Rating
IP67
Operating Temperature
-40 to 85 ºC
-40 to 185 ºF
Applications
Industrial automation & Off-highway equipment
Datasheet
Compliance
12 Inputs, 12 Proportional & 2 Relay Outputs Controller, 2 SAE J1939, Ethernet
Interface Module, 16 Inputs, 15 Outputs, SAE J1939
0-200 mA to 4-20 mA Isolated Current Converter, DIN Rail Mount
10 Inputs, 1 Analog & 8 Relay Outputs Controller, SAE J1939
4 Universal Input CAN Controller, +5V/8V Reference with Feedback Signal, SAE J1939
0-10V to 100 Hz PWM Signal Converter, DIN Rail Mount
Magnetic Pickup Input to CAN Converter, SAE J1939, Auto-Baud-Rate Detection
1 Input, 1 Output, Isolated Signal Converter, SAE J1939
0-5V to 485 Hz PWM Signal Converter, DIN Rail Mount
0-10V to 475 Hz PWM Signal Converter, DIN Rail Mount
0-5V to 100 Hz PWM Signal Converter, DIN Rail Mount
4-20mA to 550 Hz PWM Signal Converter, DIN Rail Mount
Wake-On-Charge Module, CAN 2.0B, SAE J1772 Compliant
Universal Signal Converter with Three-way Isolation, DIN Rail Mount
4-20mA to Bipolar Current (10-310mA) Converter, DIN Rail Mount
+/-10V to Bipolar Current (10-310mA) Converter, DIN Rail Mount
0-10V to Bipolar Current (200mA) Converter, DIN Rail Mount
RS-232 to CAN Converter with Two Digital Inputs, SAE J1939
PWM to 0-10V Voltage Converter, 100ms, Isolated, 24VDC, DIN Rail Mount (PWMI-WG8-06)
PWM to 0-20mA Current Converter, 100ms, Isolated, 12/24 VDC, DIN Rail Mount
PWM to 4-20mA Current Converter, 100ms, Isolated, 12/24 VDC, DIN Rail Mount
PWM to 0-5V Voltage Converter, 100ms, Isolated, 12/24 VDC, DIN Rail Mount
PWM to 0-10V Voltage Converter, 100ms, Isolated, 12/24 VDC, DIN Rail Mount
18 Cell Battery Substack Voltage Monitor, SAE J1939
PWM to 0-200mA Current Converter, <40 ms, 24VDC, DIN Rail Mount
PWM to 0-20mA Current Converter, <40 ms, 24VDC, DIN Rail Mount
0-200mA to 485 Hz PWM Signal Converter, DIN Rail Mount
PWM to 4-20mA Current Converter, 100ms, 24VDC, DIN Rail Mount (PWMI-WG8-08)
LVDT/RVDT Simulator (60° Phase Difference), DIN Rail Mount
LVDT/RVDT Simulator (<1° Phase Difference), DIN Rail Mount
LVDT/RVDT Simulator (10° Phase Difference), DIN Rail Mount
Magnetic Pickup Input to CAN Converter, SAE J1939, 250 kbps
Magnetic Pickup Input to CAN Converter, CANopen®
Magneto-Resistive Speed Sensor Input Controller, CANopen®
4 Digital Inputs Controller, SAE J1939, Ethernet
1 Digital Input, 2 Relay Outputs, CAN Controller, Isolated SAE J1939, DIN Rail Mount
12 Inputs, 8 Relay Outputs Module, SAE J1939, 1 Mbps
12 Inputs, 8 Relay Outputs Module, CANopen®, LED Indicator
Isolated, Dual Channel, Universal Signal CAN Converter, SAE J1939, NFC, DIN Rail Mount
Economy Dual Channel Universal Signal Converter, SAE J1939, 250 kbps
Economy Dual Channel Universal Signal Converter, CANopen®
Economy Dual Channel Universal Signal Converter, SAE J1939, 500 Kbps
Economy Dual Channel Universal Signal Converter, SAE J1939, 1 Mbps
Isolated Dual Channel Universal Signal Converter, SAE J1939
Isolated Dual Channel Universal Signal Converter, CANopen®
12 Inputs, 8 Relay Outputs Module, SAE J1939, LED Indicator
12 Inputs, 8 Relay Outputs Module, SAE J1939, 250 kbps
12 Inputs, 8 Relay Outputs Module, SAE J1939, 500 kbps
CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converter, Isolated SAE J1939, 250 kbps
CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converter, Isolated CANopen®
CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converter, Isolated SAE J1939, 500 kbps
CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converter, Isolated SAE J1939, 1 Mbps
CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converters (Compact), SAE J1939
CAN to 2 Analog/Digital Isolated Signals and 1 Relay Output Converters (Compact), CANopen®
Bipolar Input, 1 Relay and 1 Analog Signal Output Controller, SAE J1939, NFC, DIN Rail Mount
6 Digital Inputs Controller, SAE J1939, Auto-Baud-Rate Detection
4-20mA to 0-200mA Current Converter, DIN Rail Mount
4-20mA to 20-160mA Current Converter, DIN Rail Mount
4-20mA to 0-50mA Current Converter, DIN Rail Mount
4-20mA to 40-160mA Current Converter, DIN Rail Mount
4-20mA to 0-100mA Current Converter, DIN Rail Mount
4-20mA to 0-160mA Current Converter, DIN Rail Mount
4-20mA to 20-200mA Current Converter, DIN Rail Mount
4 Universal Signal Inputs Controller, SAE J1939
4 Analog Signal Outputs CAN Controller, SAE J1939, 250 kbps
4 Analog Signal Outputs CAN Controller, CANopen®
4 Analog Signal Outputs CAN Controller, SAE J1939, 500 kbps
4 Analog Signal Outputs CAN Controller, SAE J1939, 1Mbps
4 Universal Signal Outputs CAN Controller, SAE J1939, Compact
4 AC Voltage or Current Inputs, 4 Analog Outputs CAN Controllers, SAE J1939, DIN Rail Mount
3 Encoder, 7 Signal Inputs CAN Controllers, Isolated, SAE J1939, 250 kbps
3 Encoder, 7 Signal Inputs CANopen® Controllers, Isolated
3 Encoder, 7 Signal Inputs CAN Controllers, Isolated, SAE J1939, 500 kbps
3 Encoder, 7 Signal Inputs CAN Controllers, Isolated, SAE J1939, 1 Mbps
4 Universal Signal Outputs CAN Controller, SAE J1939
4 Universal Signal Outputs CAN Controller, CANopen®
4 Channel Strain Gauge CAN Controller with Wire Break Detection, SAE J1939
4 Channel Strain Gauge CAN Controller with Wire Break Detection, CANopen®
I/O Module, 12 Inputs, 8 Analog and 1 Relay Outputs, SAE J1939
12 Inputs, 8 Analog and 1 Relay Outputs CAN I/O Module, CANopen®
20 TC, 2 PT100 RTD, and 4 Universal Inputs, 6 Relay Outputs Controller, 2 SAE J1939, Ethernet
18 Digital Signal Inputs CAN Controller, SAE J1939
18 Digital Signal Inputs CAN Controller, CANopen®
18 Digital Signal Inputs, CAN Controller, SAE J1939, 54 CAN Transmit Messages
2 Bipolar Analog/Digital, 8 Universal Signal Inputs Controller, CAN (SAE J1939), Ethernet, 2 +5V Ref., DIN Rail Mount
2 Bipolar Analog/Digital, 8 Universal Signal Inputs Controller, CANopen®, Ethernet, 2 +5V Ref., DIN Rail Mount
2 Bipolar Analog/Digital, 8 Universal Signal Inputs Controller, CAN (SAE J1939), 2 +5V Ref., DIN Rail Mount
10 Universal Signal Input CAN Controller, SAE J1939
10 Universal Signal Input CAN Controller, +5V Ref., SAE J1939
10 Universal Signal Input CAN Controller, CANopen®
11 Inputs and 4 Analog, 4 Relay, 1 Valve Outputs CAN Controller, 2 SAE J1939
11 Inputs and 4 Analog, 4 Relay, 1 Valve Outputs CAN Controller, 2 CANopen®
1 Signal Input (V/I/PWM) to CAN Converter, SAE J1939
1 Signal Input (V/I/PWM) to CAN Converter, CANopen®
CAN to Sine or Square Wave and PWM Output Controller, 2 SAE J1939
Center Bonded Mounts STA Series
Automation
Power Management
Connectivity Solutions
Machine Control
Accessories